Case studies · Pharmaceuticals · South Gujarat

Two smart heatless dryers at a pharma plant: −40 °C PDP held, purge cut from 18 % to 8 %

Pharmaceutical formulations plant, South Gujarat · 2 × AIRS smart heatless dryers with TSE Control, with filters

  • −40 °C PDP on both dryers (at commissioning and in service)
  • 18 → 8 % Purge air (93 m³/h handed back to the plant)
  • ₹8.4 L Saved per year (₹41.9 lakh over five years)
  • 64 t CO₂ avoided a year (90 MWh not drawn)

The challenge

A pharmaceutical formulations plant in hot, humid South Gujarat needed instrument and product-contact air at −40 °C pressure dew point, with air reaching the dryers at 40–47 °C. A conventional heatless dryer meets −40 °C — by venting about 18 % of the air it dries, on a fixed clock, whether the plant is busy or quiet.

What AIRS did

  1. Two complete smart heatless packages, each sized for 275 cfm at 9 barg, with its own 0.01 µm coalescing pre-filter and 1 µm particulate after-filter.
  2. TSE Control watches the outlet PDP: each tower keeps adsorbing while the air stays dry, and the dryer holds in standby once −40 °C is reached — restarting by itself when needed.
  3. Extruded aluminium towers, a swirl diffuser that spreads the air over the whole desiccant bed, and a low-loss valve manifold: 0.2 bar across the dryer.
  4. Energy saving worked out for the client's own duty and tariff in the offer, before the order was placed.

The result

  • −40 °C PDP reached at commissioning on both dryers and confirmed again in operation.
  • Purge cut from 18 % to 8 % — 56 % less, 93 m³/h (55 cfm) of dried air kept in the plant every hour.
  • 10.3 kW less compressor power, round the clock: ₹8.4 lakh a year, ₹41.9 lakh over five years and 64 t CO₂ a year.
  • The client has since come back to AIRS for zero air loss drains, dryer filter kits and service.

Both dryers, per year (8,760 h)

Fixed-timer heatlessAIRS with TSE Control
Purge air18 %8 %
Air vented168 m³/h75 m³/h
Compressor power for purge18.5 kW8.2 kW
Energy a year162,078 kWh72,035 kWh
Cost a year₹15.1 lakh₹6.7 lakh
Saving—₹8.4 lakh

From offer to repeat orders

  • Jul 2024: Offer with the purge saving worked out for the plant's duty
  • Sep 2024: Order for both dryer packages, filters included
  • Nov–Dec 2024: Both packages supplied to site
  • Jan 2025: Commissioned — −40 °C PDP reached on both dryers in PDP control
  • Feb 2025: Performance check: −40 °C confirmed in operation
  • 2025–26: Repeat orders: zero air loss drains and dryer filter kits

Basis of calculation

Client tariff ₹9.3 per kWh · 2 × 275 cfm design flow = 934 m³/h · 8,760 h a year · compressor 0.11 kWh per m³ · grid 0.71 kg CO₂ per kWh. 18 % is the average purge of a heatless dryer of this size on a fixed timer at full flow.

At a glance

Dryers2 × smart heatless, TSE Control
Design flow275 cfm each at 9 barg
Pressure range4–14 barg
Inlet air40–47 °C
Required PDP−40 °C
Pressure drop0.2 bar
Filters0.01 µm pre · 1 µm after
CommissionedJanuary 2025

About the equipment · Book an energy saving assessment

Client name withheld under the AIRS confidentiality policy. References are shared on request with the client's consent.